The importance of supervised monitoring modules used in management and monitoring of extinguishing systems

In many locations from chemistry laboratories to industrial amenities, to have the ability to guarantee the protection of life and property against a attainable fire hazard, extinguishing methods are used in addition to detection and alarm methods. It can be extremely essential that the extinguishing techniques put in could be triggered by the fire extinguishing control panel, in order to eliminate a possible fire with early intervention.
In order to satisfy these wants, and with 35 years of sectoral information and expertise, Mavili Elektronik offers:
Maxlogic Conventional Fire Extinguishing Control Panel operating based on the cross-zone detection precept;
Maxlogic Extinguishing Status Indicator Unit, which allows the distant performance of the indications and controls on the Control Panel;
Maxlogic Extinguishing Output Expansion Panel;
Maxlogic Extinguishant Manual Release Button, which allows the extinguishing course of to be started manually and remotely; and
to ensure that the extinguishing course of can be paused, Maxlogic has produced the Extinguishant Emergency Stop Button.
All these gadgets are produced utilizing surface-mount know-how and are geared toward making the automation of the extinguishing system and hearth and gas detection system good.
Image copyright: Mavili
Mavili Elektronik develops its products by at all times considering the wants of the installation. In Deadline that require the mixing of the extinguishing system with the intelligent addressable hearth detection system, it provides solutions via the monitoring modules that even have a ‘supervised’ possibility.
Supervised monitoring modules play an important role in controlling the continuity of the cable connection between the loop and the extinguishing system. Failure to detect a potential open or short circuit in the wiring between the contact monitoring modules and the peripheral methods can cause disruption of the triggering, with doubtlessly critical penalties. For this purpose, when choosing monitoring modules, it must be taken into consideration that they’ve supervised options.
Image copyright: Mavili
Since Maxlogic clever addressable fire detection and alarm management panels are continually speaking with ‘supervise’ contact monitoring modules related to cable loops and compliant with EN 54-17 and EN 54-18 requirements, it makes it simpler to watch conditions such as open circuits and brief circuits that may occur within the system. Many duties could be performed in the fireplace extinguishing installation, such because the control and monitoring of all valves that may interrupt the move of water, water flow alarm switches, strain switch, and electrical or diesel hearth pumps.
By including two contact monitoring modules to 2 separate relay outputs positioned above the Maxlogic Conventional Fire Extinguishing Control Panel, one of many modules can be used to control errors and the opposite to regulate the hearth scenario, monitoring and control of the extinguishing system through an intelligent addressable hearth detection and alarm system could be carried out successfully.
For extra info, go to www.mavili.com.tr/en
Share

Leave a Comment